JA-162PC, Wireless motion detector with photo camera
This device is a wireless part of the JABLOTRON system. It serves for the detection of human movements in the interior of buildings and visual alarm confirmation. The camera takes color photos with a resolution of up to 640x480 pixels.
The camera is equipped with a visible flash to take photos in the dark. The images are stored in the internal memory of the detector and are then transferred to the control panel and from the control panel they can be sent to MyJABLOTRON or ARC. The detector can also take a photo on request.
The detector occupies one position in the system and must be installed by a trained technician with a valid certificate issued by an authorized distributor.
The photo verification can only be used after registering the system with MyJABLOTRON or with a subsequent ARC service.
This device is compatible with control panels JA-103K, JA-107K, JA-102K and higher models.
Specifications:
Current | 2x lithium battery type CR123A 3 V/1.5 Ah |
---|---|
Typical battery life | about 2 years (1 activation and 1 series of photos per day) Please note: batteries are not included |
LowBatt voltage | ≤2.8V |
Quiescent current consumption | 90 µA |
Maximum power consumption | 700mA |
Communication frequency | 868.1 MHz, JABLOTRON protocol |
Maximum radio frequency power (ERP) | 11mW |
Communication range | approx. 300 m (unrestricted area) |
Recommended installation height | 2.5 m above the floor |
PIR detection angle/detection coverage | 90°/12 meters |
Horizontal camera shooting angle | 90° |
Range of the flash | maximum 3 meters |
Camera resolution | LQ 320x240; HQ 640 x 480 pixels |
Photo format LQ/HQ | 5–20 KB/5–64 KB |
Typical (LQ) photo transmission time to the control panel | up to 20 s (10 s) |
Typical (HQ) photo transmission time to the control panel | up to 130 s (60 s) |
Typical time for transferring photos to the server | 15 seconds/GPRS; 2 seconds/LAN |
Dimensions, weight (without batteries) | 150 x 65 x 44 mm, 130 grams |
Operational temperature range | -10 °C to +40 °C |
Operational environment | In general |
Average operational humidity | 75% RH, without condensation |
Classification | Safety class 2/Environmental class II (EN 50131-1) |
Certification Body | Trezor Test No. 3025 |
Corresponds to | EN 50131-1, EN 50131-2-2, EN 50131-5-3, EN 50131-6, EN 55032, ETSI EN 300 220-1,-2, EN 62368-1, EN IEC 63000 |
Can be operated according to | ERC/REC-70-03 |
Recommended screw | 2 x ø 3.5 x 40 mm (countersunk head) |